Heyl 

Heyl
DVGW Certified UV-Systems Series A-LCD Aqua UVtron

Heyl  DVGW Certified UV-Systems Series A-LCD Aqua UVtron
For the disinfection of drinking water up to 38 °C incl. selective UV-C control unit certified acc. to DVGW / ÖVGW.

Electro-polished st. steel chamber 316 l V4A 1.4404 with st. steel sample taps at the entrance and exit of the system, mounted UV-sensor holder with selective UV-C sensor at 254 nm acc. to DVGW W-294 and Ö-Norm 5873-1, vent and drain plug, build-in turbulator, UV-C amalgam low pressure lamp built in hard quartz sleeve F240.

Microprocessor controlled monitor with backlight alphanumeric LCD display for indication of absolute measured UV-C intensity in W / m2, operational hours, start-up and power failure counter displayed in addition to optional measured water flow and water temperature. LEDs for 'Operation', 'Cleaning' and 'Fault' signalisation and ON / OFF button, input contacts for remote ON / OFF, potential free relay contacts for pre-alarm and alarm, 4 to 20 mA signal output proportional to the measured UV-C intensity. Relay output contacts for the control of a flush valve depending on the temperature threshold programmed.
 TypeFlow rate
m3 / h
Power
W
ConnectionDimens­ions
(W x D x H)
mm
PUOrder No.in StockPrice/Unit/EUR 
 A27-LCD Aqua UVtron2.355hydraulic connection R 1" AG236 x 244 x 92515437714-on demand 
 A46-LCD Aqua UVtron2.780hydraulic connection R 1 ¼" AG261 x 269 x 53315437715-on demand 
 A90-LCD Aqua UVtron9.0150hydraulic connection R 1 ½" AG261 x 269 x 94215437716-on demand 
 A180-LCD Aqua UVtron17.5230hydraulic connection DN 65360 x 295 x 119815437717-on demand