Systec
Horizontal Pass-Through Autoclaves H Series 2D

Standard features:
  • Integrated, separate steam generator.
  • Housing, support frame and pressure vessel made of corrosion-resistant st. steel.
  • Temperature and pressure range 140 °C, 4 bar.
  • Touch-screen control.
  • Number of sterilisation programmes: up to 100.
  • Code-secured access rights for changing parameters and further safety-relevant intervention.
  • Internal memory for storing up to 500 sterilisation cycles.
  • Timer for starting programmes.
  • Flexible PT-100 temperature sensor.
  • Additional temperature sensor in condense exhaust.
  • Temperature holding function for liquids after programme finish.
  • Special programme for Durham tubes.
  • Calculation of F0 value.
  • Special programme for waste sterilisation with pulsed heat-up for more efficient air exhaust.
  • Water-cooled steam exhaust, thermostatically controlled.
  • Programmable automatic door-opening on completion of programme.
  • RS-232 and RS-485 interfaces for external data transmission (network-compatible).
Triple safety aspects:
  • Only one door can be opened at a time. If one door is open, the other is automatically locked.
  • If the autoclave is switched off or if no current is available (e. g. power failure), both doors remain locked.
  • If the door at the non-sterile side is opened, a sterilisation programme has to be performed before the door at the sterile side can be opened.

The locking system can be adapted to customers' wishes. Doors and control panel are made of heat-insulating plastic, the housing completely of st. steel and the st. steel edges specially processed for smooth junctions with walls. Operation, however, can be carried out from both sides, the position (open or closed) of the opposite door being indicated on the display.

For use under the most stringent clean room and safety conditions:
  • For biological safety laboratories: fitting as a sterilisation and pass-through lock for protecting the external environment.
  • For clean rooms in laboratories and production facilities: as a sterilisation and pass-through lock separating sterile and non-sterile areas.
 TypeChamber
dimens­ions Ø x D
mm
Chamber volume
total / nominal
l
Dimens­ions
(H x W x D)
mm
Mains supplyPUOrder No.in Stock 
 Systec HX-90 2D400 x 75098 / 901430 x 690 x 1160380 to 400 V, 50 / 60 Hz, 16 A15439855-on demand
 Systec HX-150 2D500 x 750155 / 1501530 x 790 x 1200380 to 400 V, 50 / 60 Hz, 16 A15439856-on demand
 Systec HX-200 2D500 x 1000205 / 2001530 x 790 x 1450380 to 400 V, 50 / 60 Hz, 16 A15439857-on demand
 Systec HX-320 2D740 x 750370 / 3201683 x 930 x 1210380 to 400 V, 50 / 60 Hz, 32 A15437367-on demand
 Systec HX-430 2D740 x 1000480 / 4301683 x 930 x 1460380 to 400 V, 50 / 60 Hz, 32 A15437368-on demand
 Systec HX-540 2D740 x 1250590 / 5401683 x 930 x 1710380 to 400 V, 50 / 60 Hz, 32 A15437369-on demand
 Systec HX-650 2D740 x 1500700 / 6501683 x 930 x 1960380 to 400 V, 50 / 60 Hz, 32 A15437370-on demand
 Systec HX-780 2D1000 x 1000870 / 7801850 x 1255 x 1750380 to 400 V, 50 / 60 Hz, 32 A15437371-on demand
 Systec HX-980 2D1000 x 12501070 / 9801850 x 1255 x 2000380 to 400 V, 50 / 60 Hz, 32 A15437372-on demand
 Systec HX-1180 2D1000 x 15001270 / 11801850 x 1255 x 2250380 to 400 V, 50 / 60 Hz, 32 A15437373-on demand
 Systec HX-1380 2D1000 x 17501470 / 13801850 x 1255 x 2500380 to 400 V, 50 / 60 Hz, 32 A15437374-on demand
 Systec HX-1580 2D1000 x 20001670 / 15801850 x 1255 x 2750380 to 400 V, 50 / 60 Hz, 32 A15437375-on demand
Systec autoclaves are delivered ready for subsequent installation of all options.
Further options and special programmes as well as baskets and inserts, transport and loading systems on request.